Marbon Solid Surface Material Tested Result-1

玛宝实体面材检测结果  -1

No

Property

Test Method/Requirement

Results

1

Density, g/cm3

ASTM D792

1.6

2

Tensile Strength, Mpa

ASTM D638

28.4

(Clause A.2 OF ICPA-SS-1-1997)

3

Tensile Modulus, Mpa

Crosshead speed: 5mm/min

9,600

(Clause A.2 of ICPA-SS-1-1997)

4

Elongation at Break, %

 

0.43

(Clause A.2 of ICPA-SS-1-1997)

 5.

Flexural Strength, Mpa

ASTM D790

44.6

(Clause A.1 of ICPA-SS-1-1997)

Crosshead speed :

6

Flexural Modulus, Mpa

5 mm/min

7,400

(Clause A.1 of ICPA-SS-1-1997)

7

Izod Impact Resistance

ASTM D256

14.5

(notched), J/m

 Pendulum used : 2 J

(Clause A.3 of ICPA-SS-1-1997)

8

Barcol Hardness

ASTM D2583

60

(Clause A.4 of ICPA-SS-1-1997)

9

Coefficient of Linear Thermal

ASTM E831

86.9

Expansion, x 10-6 / ºC

10

Water Absorption, %

ASTM D570

0.06

(24 h immersion at room temperature) 

11

Cigarette Burn

ANZI Z124.6.5.4

No ignition or progressive glow of the surface during or after contact with the lighted cigarettes was observed.

Requirement :

(Clause 5.3 of ICPA-SS-1-1997)

There shall be no ignition or progressive glow of the surface during or after contact with the lighted cigarettes.

12

Chemical Resistance Test

Specimens was immersed in the specified chemical for 24 hours.Colour difference ( E) was determined using colour spectrophotometer.

a)  E = 3.18
  a) 20% nitric asid
  b) 20% sulphuric acid b   E = 7.63
  c) Ammonia c)  E = 5.38
  d) Acetone d) Specimen disintegrates

13

Impact Resistance :

ANZI Z124.6.4.2.1

No sign of cracks or chips were observed.

 

(Clause 4.1 of ICPA-SS-1-1997)

Requirement : 

  a) Point Impact

The sample shall not show any cracks or chips when 0.225 kg of 38 mm diameter steel ball was dropped from a height of 610 mm

  b) Knife Drop Test

ANZI Z124.6.4.2.2

No sign of cracks or fractures were observed.

 

Requirement :

 

The sample shall not show any cracks or chips when 0.225 kg of 38 mm diameter steel ball was dropped from a height of 610 mm

  c) Skillet Drop Test

ANZI Z124.6.4.2.3

No sign of cracks or fractures were observed

 

Requirement :  

 

The sample shall not show any cracks or chips when 26 cm cast iron skillet was dropped from a height of 305 mm.

14

 Stain Resistance Test 

ANZI Z124.6.5.2

 
 

 (Clause 5.2 of ICPA-SS-1-1997) 

Requirement :

 
   

The maximum allowable total rating shall be 64.

 
  1.Black Crayon (Panel)   3
   2.Black Liquid Shoe Polish (Kiwi)   3
  3.Blue Washable Ink (Parker)   2
   4.Gentian Violet Solution   4
  5. Vegetable Juice 1 (V8 Campbell)   1
   6. Grape Juice (Gerber)   1
  7. Lipstick (Nutrimetics)   2
  8. Hair Dye (Wella)   5
  9. Savlon Antiseptic2   1
  10. Wet Tea Bag (Lipton)   1
  Total Rating (uncovered + covered ) = 47